Optimalisasi Pencahayaan Alami pada Ruang Studi Kasus: Gedung Prodi Arsitektur Universitas Malikussaleh

Nurhaiza, Nurhaiza and Nova, Purnama Lisa (2016) Optimalisasi Pencahayaan Alami pada Ruang Studi Kasus: Gedung Prodi Arsitektur Universitas Malikussaleh. ARSITEKNO, 7 (7). pp. 33-42. ISSN 2301-945X

[img]
Preview
Text
Jurnal ARSITEKNO FT Arsitektur Unimal Vol. No.7 Januari 2016 Hal.33-42.pdf

Download (4MB) | Preview
Official URL: http://arsitekno.unimal.ac.id/

Abstract

Natural lighting is the lighting obtained from direct sunlight, where the light is obtained in the morning until late afternoon. According to SNI 03-2396-200, natural lighting during the day can be good in a span of solar orientation starting at 8:00 pm until 16: 00 pm with equitable distribution of incoming light in the room and did not leave annoying glare effects in the use of lighting natural, regardless of the quality and distribution of light that enters the building through a window and orientation of openings. The wider the aperture, the more light that enters the room. It is necessary to control the amount of light coming into the room. The research used is quantitative method by using mathematical models, with the measurement process, using a formula to obtain accurate data. The object of research and observations in Architecture Program Faculty Building University of Malikussaleh, Lhokseumawe Aceh. Observation is by direct observation to see the condition of natural lighting in classrooms, measurements the extent of the classroom. Then collect some measurement data among other things, measure the light intensity at the lecture hall by using Luxmeter, calculate the intensity of light at the lecture hall by factors sky with measuring point main and the measuring point side and the comparative results of the measurement of light intensity of the lighting level the average recommended. The results show, a lecture hall in the building Prodi architecture has three floors, which have 4 lecture room on floors 1 and 2, 2 room studio regular on floors 1, 2 lab computer room on the floor and 2 studio design room on the 2nd floor. also of course the building also has other equipment such as administration room, warehouse and other supporting facilities. But for the third floor untapped dikarenaka still in the process of renovation. The results of observations obtained intensity of natural light on the 1st floor and 2nd floor Architecture Program building University of Malikussaleh based on the measurement of light intensity using the luxmeter, the obtained data is that the rooms was not in accordance with the standards of an average lighting is recommended by ISO 2000 for classrooms -03 250 lux and 700 lux. Key word: Natural Lighting, Light Intensity, Lux meters, ISO 2000, SNI 03-2396-200

Item Type: Article
Subjects: T Technology & Engineering > TM Architecture
Divisions: Faculty of Engineering > Department of Architecture Engineering
Depositing User: Nova Purnama Lisa ST., M.Sc
Date Deposited: 25 May 2016 02:41
Last Modified: 25 May 2016 02:41
URI: http://repository.unimal.ac.id/id/eprint/1392

Actions (login required)

View Item View Item